Vacuum pumps without lubrication G series - 10-25 mc/h

Vacuum pumps without lubrication G series - 10-25 mc/h

Characteristics

Gamavuoto 10 to 25 m3/h oil-less pumps do not require lubrication thanks to the use of vanes and covers in special graphite and it strongly reduce maintenance operations since no topping up is required.

In the “G” series the electric motor is connected to the body of the pump through a flexible connector and this allows the use of different kinds of motors (DC power, ADPE,
ATEX, and so on…)

Equipped with silencers which strongly reduce the noise level, these pumps can also be requested with a single-phase motor.

Installation

Connect up the vacuum circuit. Set up the electrical connections to the motor and check that the pump is rotating in the right direction. WARNING! If the electrical motor rotates in the wrong direction, the suction unit could be damaged.

Art. Volume aspiratoVacuum flowVakuum-Durchsat Press. finaleFinal pressure ABSEnddruck VelocitàRpmGeschwindigkeit Potenza motoreMotor powerMotorleistung PesoWeightGewicht A B C D E F G I
50 Hz
Mc/h
60 Hz
Mc/h
mbar (ass.) 50 Hz
g/min
60 Hz
g/min
50 Hz
Kw
60 Hz
Kw
kg
GPOS 10/G 10 12 80 1450 1700 0.55 0.66 24 130 230 340 430 135 193 1/2" 8.5
GPOS 15/G 15 18 80 1450 1700 0.55 0.66 27 130 230 340 450 135 193 1/2" 8.5
GPOS 20/G 20 24 80 1450 1700 0.88 1 31 130 270 340 470 135 193 1/2" 8.5
GPOS 25/G 25 30 80 1450 1700 0.88 1 33 130 270 385 490 135 193 3/4" 8.5